Cisco Systems 4 Video Gaming Accessories User Manual


  Open as PDF
of 1040
 
25-98
Cisco Prime Network 4.0 User Guide
OL-29343-01
Chapter 25 Monitoring Mobile Technologies
LTE Networks
Viewing the IP Source Violation Details
A Source violation occurs when a mobile device sources packets to the PDSN with a IP address that is
different from the one specified during setup. Using this feature, the packets that need not be sent over
the network are dropped when it tries to pass through PDSN.
To view the IP Source Violation configuration details for a PDSN service:
Step 1 Right-click the required device in Prime Network Vision and choose Inventory.
Step 2 In the logical inventory window, choose Logical Inventory > Context > Mobile > PDSN > PDSN
service > IP Source Violation. The details are displayed in the content pane.
Table 25-59 displays the IP Source Violation configuration details.
Viewing the MSID Configuration Details
To view the Mobile Station ID (MSID) configuration details for a PDSN service:
Step 1 Right-click the required device in Prime Network Vision and choose Inventory.
Step 2 In the logical inventory window, choose Logical Inventory > Context > Mobile > PDSN > PDSN
service > MSID. The details are displayed in the content pane.
Table 25-60 displays the MSID configuration details.
Table 25-59 IP Source Violation Configuration Details
Field Description
Clear on Valid Packet Indicates whether the service to reset the negotiation and drop limit counters
upon receipt of properly addressed packet is enabled. By default, this feature
is disabled.
Drop Limit The maximum number of IP source violations within the detection period,
before the call is dropped. This number can be any value between 0 and
1000000, and defaults to 10.
Period The detection period (in seconds) for the IP source violation. This field can
be any value between 1 and 1000000, and defaults to 120.
Renegotiation Limit The maximum number of IP source violations within the detection period
before renegotiating PPP for the call. This field can be any value between 1
and 1000000, and defaults to 5.
Table 25-60 MSID Configuration Details
Field Description
MSID Length Max The maximum length of the MSID configured for the PDSN service. This
length can be any value between 10 and 15, and defaults to 15.
MSID Length Min The minimum length of the MSID configured for the PDSN service. This
length can be any value between 10 and 15, and defaults to 10.