Cisco Systems MDS 9000 Video Gaming Accessories User Manual


 
Send documentation comments to mdsfeedback-doc@cisco.com.
20-15
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-6965-03, Cisco MDS SAN-OS Release 2.x
Chapter 20 iSCSI Configuration
Configuring iSCSI
when a new iSCSI host is added. On the storage array, all LUNs that are used by iSCSI initiators are
configured to allow access by the proxy initiator’s pWWN. From the iSCSI perspective, this
configuration is no different from the default mode (see Figure 20-10).
Figure 20-10 iSCSI View of a Proxy Initiator
From the Fibre Channel perspective, only one Fibre Channel initiator is visible per VSAN (see
Figure 20-11).
Figure 20-11 Fibre Channel View with a Proxy Initiator
iSCSIiSCSI
iSCSIiSCSI
iSCSIiSCSI
FCFC
Iqn.host-1
Ip 10.1.1.2
Iqn.host-2
Ip 10.1.1.3
Iqn.host-3
Ip 10.1.1.4
pWWN-P5
nWWN-N5
FCID-XXXX05
pWWN-P6
nWWN-N6
FCID-XXXX06
IP network
105221
IP-10.1.1.1
Fibre Channel
Fabric
iSCSIiSCSI
FCFC
Host-2
IP 10.1.1.3
pWWN-P5
nWWN-N5
FCID-XXXX05
pWWN-P6
nWWN-N6
FCID-XXXX06
pWWN-P9
nWWN-N9
FCID-XXXX09
105223
IP-10.1.1.1
Fibre Channel
Fabric
One virtual Fibre Channel
host for an IPS port