Mitsubishi Electronics FXCPU Video Game Controller User Manual


 
34 Applied Instructions (FX3U-CF-ADP)
34.3 FLWR / Data write
783
FXCPU Structured Programming Manual
[Basic & Applied Instruction]
31
Applied Instructions
(Data Transfer 3)
32
Applied Instructions
(High Speed
Processing 2)
33
Applied Instructions
(Extension File
Register Control)
34
Applied Instructions
(FX
3U
-CF-ADP)
35
Interrupt Function
and Pulse Catch
Function
A
Relationships
between devices
and addresses
B
Applied
Instruction List
Detailed explanation of setting data
Details of the setting data in the FLWR instruction are as shown below.
Setting items Description Data Type
File ID
K0 to K63
ANY16
Head of devices which store data to be written.
Specify the head of devices which store the data to be written to the CompactFlash
TM
card.
ANY_SIMPLE
Data write parameter
Specify the data writing type
K0 : Mixed type
K1 : Bit type
K2 : Decimal type (16-bit)
K3 : Decimal type (32-bit)
K4 : Hexadecimal type (16-bit)
K5 : Hexadecimal type (32-bit)
K6 : Real numbers(Floating point data) Exponent expression type (32-bit)
K7 : Character string (512 half-width/full-width characters maximum)
K8 : Data name :Character string consisting of up to 32 half-width/full-width
characters. Index, DATE TIME are added automatically.
ARRAY [0..4]
OF ANY16
+1
Specify the line position of the writing destination, or specify additional writing.
Line position of the writing destination : K1 to specified maximum number of lines
Additional writing : K-1
+2
Specify the data column position in the writing destination.
Column position : K1 to K254
Additional writing : K-1
+3
Number of written data points
K1 to K254
+4
Writing destination
K0 : CompactFlash
TM
card
K1 : Buffer inside the CF-ADP
Channel number used by the CF-ADP
K1 : ch1
K2 : ch2
ANY16
Line position after writing
K1 to specified maximum number of lines
ARRAY [0..1]
OF ANY16
+1
Column position after writing
K1 to K254