20 Applied Instructions (Positioning Control)
20.4 DABS / Absolute Current Value Read
526
FXCPU Structured Programming Manual
[Basic & Applied Instruction]
Cautions
1) The instruction is provided in the FX2N and FX2NC PLCs Ver. 3.00 or later.
2) Since ABS data is read out in pulse converted value, please specify "Motor system" for parameter setting
(BFM#3) of FX
2N-1PG. (FX2N, FX2NC, FX3U, FX3UC PLCs.)
3) Writing of ABS data into FX
2N-10PG should be addressed to the current value registers (BFM#40, #39) in
which the pulse converted values are stored. (FX
2N, FX2NC, FX3U, FX3UC PLCs.)
4) Some restrictions to applicable devices.
S1: Please designate the transistor output.
S2: The FX
3U and FX3UC PLCs only are applicable, index (V, Z) decoration is disabled.
S3: The FX
3G, FX3GC, FX3U and FX3UC PLCs only are applicable.
S4: The FX
3U and FX3UC PLCs only are applicable.