33 Applied Instructions (Extension File Register Control)
33.2 SAVER / Save to ER
753
FXCPU Structured Programming Manual
[Basic & Applied Instruction]
31
Applied Instructions
(Data Transfer 3)
32
Applied Instructions
(High Speed
Processing 2)
33
Applied Instructions
(Extension File
Register Control)
34
Applied Instructions
(FX
3U
-CF-ADP)
35
Interrupt Function
and Pulse Catch
Function
A
Relationships
between devices
and addresses
B
Applied
Instruction List
Setting data
HFFFFR2047
R0 K100
R1 K105
R10 K200
R11 K215
Device number
Current
value
Extension registers (R)
R12 K400
R19 K350
R99 K1000
R100 HFFFF
HFFFFR127
Changed dataUnused
HFFFFR128
HFFFFR255
HFFFFR256
HFFFFR1919
HFFFFR1920
Setting data
2)
SAVER
instruction
K2048
1st
operation
cycle
Setting backup data
K128
Number of
already
written
points (D0)
K256
K1920
2nd
operation
cycle
3rd to 15th
operation
cycle
16th
operation
cycle
HFFFFER2047
ER0 K100
ER1 K105
ER10 K200
ER11 K215
Device number
Current
value
Extension file registers (ER)
ER12 K400
ER19 K350
ER99 K1000
ER100 HFFFF
HFFFFER127
HFFFFER128
HFFFFER255
HFFFFER256
HFFFFER1919
HFFFFER1920