Mitsubishi Electronics FXCPU Video Game Controller User Manual


 
13 Applied Instructions (Handy Instruction)
13.1 IST / Initial State
317
FXCPU Structured Programming Manual
[Basic & Applied Instruction]
11
Applied Instructions
(Data Operation)
12
Applied Instructions
(High Speed
Processing)
13
Applied Instructions
(Handy
Instruction)
14
Applied Instructions
(External FX I/O
Device)
15
Applied Instructions
(External Device
(optional device))
16
Applied Instructions
(External Device)
17
Applied Instructions
(Data Transfer 2)
18
Applied Instructions
(Floating Point)
19
Applied Instructions
(Data Operation 2)
20
Applied Instructions
(Positioning
Control)
3. Assignment of mode select inputs
In order to use IST command, inputs of the following serial numbers must be assigned in the mode inputs.
If the numbers are not serial, or modes are partly omitted, the array is modified by using auxiliary relays as
shown below, which is used as the mode designation beginning input.
- X020: Individual operation
- X021: Return to home position
- X022: Stepping
- X023: One-cycle operation
- X024: Continuous operation
- X025: Return home start
- X026: Automatic start
- X027: Stop
In this example, M0 is used as the mode designation beginning input.
X030
M 0
Individual
operation
X035
M 1
Return to home
position
X033
M 2
Stepping
X040
M 3
One-cycle
operation
X032
M 4
Continuous
operation
X034
M 5
Return home
start
X026
M 6
Automatic start
X041
M 7
Stop
M 0
Not active
X030
M 1
Return to home
position
M 2
Not active
M 3
X031
M 4
Continuous
operation
X032
M 5
Return home
start
M 6
Automatic start
X033
M 7
Stop
M8000
RUN monitor
M8000
M 0
X030
M 1
M 2
M 3
X031
M 4
Continuous
operation
X032
M 5
M 6
Automatic start
X033
M 7
Stop
M8000
M8000
Individual
operation
When inputs are not serial numbers
(Example) X030:Individual operation
X035:Return to home position
X033:Stepping
X040:One-cycle operation
X032:Continuous operation
X034:Return home start
X026:Automatic start
X041:Stop
In the case of continuous/return
home mode only
(Example) X030:Return to home position
X031:Continuous operation
X032:Common for automatic
start and return home start
X033:Stop
In the case of continuous/
individual mode only
(Example) X030:Individual operation
X031:Continuous operation
X032:Automatic start
X033:Stop
Not active
M8000
RUN
monitor
IST
EN
s
ENO
d1
d2
M0
S20
S29