13 Applied Instructions (Handy Instruction)
13.2 SER / Search a Data Stack
326
FXCPU Structured Programming Manual
[Basic & Applied Instruction]
Cautions
1. Comparison of magnitude
To be calculated algebraically. (-10 < 2)
2. When minimum value and maximum value are present in a plurality
If there are a plurality of minimum value and maximum value in the data, the latter position is stored
individually.
3. Number of bits occupied
The search result occupies the following number of devices when this command is driven.
Please be careful not to overlap with the devices used in the control of the machine.
1) In the case of 16-bit operation
A total of five points will be occupied, that is, , +1, +2, +3, +4.
2) In the case of 32-bit operation
A total of ten points will be occupied, that is, ( +1, ), ( +3, +2), ( +5, +4),
(+7, +6), (+9, +8).
4. FXU PLC supports the command by V3.07 or higher.
5. Some restrictions to applicable devices.
S1: The FX3G, FX3GC, FX3U and FX3UC PLCs only are applicable.
S2: The FX