464
18 Applied Instructions (Floating Point)
18.8 DEADD / Floating Point Addition
FXCPU Structured Programming Manual
[Basic & Applied Instruction]
Cautions
1) When the same devices are specified, the same device numbers can be specified in and and
. In this case, when the continuous execution type instruction (DEADD) is used, it must be noted that
the addition result changes in every operation cycle.
2) The instruction is provided in the FX
3G PLC Ver. 1.10 or later.
3) Some restrictions to applicable devices.
S1: The FX
3G, FX3GC, FX3U and FX3UC PLCs only are applicable.
S2: The FX
3U and FX3UC PLCs only are applicable.
S3: The FX
3S, FX3G, FX3GC, FX3U and FX3UC PLCs only are applicable.