Mitsubishi Electronics FXCPU Video Game Controller User Manual


 
14 Applied Instructions (External FX I/O Device)
14.8 PR / Print (ASCII Code)
380
FXCPU Structured Programming Manual
[Basic & Applied Instruction]
2) Timing chart (When M8027=ON)
Related devices
*1. Cleared when changed from RUN to STOP.
Cautions
1. Command input and operation of instruction
Command input=ON : Even in the midst of continuous ON or pulse instruction execution, when the output of
one cycle is over, the execution is terminated.
M8029 operates only when M8027=ON.
Command input=OFF:All outputs are OFF.
2. Relation with scan time (operation time)
This instruction is executed in synchronism with the scan time.
If the scan time is short, it is driven by constant scan mode, or if too long, it is driven by using the timer
interrupt mode.
3. Output of PLC
Use the transistor output for the output of the PLC.
4. If 00H (NUL) exists in the data (when M8027=ON)
The instruction execution is completed, and the remaining data is not issued.
M8029 remains ON during 1 operation cycle.
5. Some restrictions to applicable devices.
S1: The FX3U and FX3UC PLCs only are applicable.
Device Name Content
M8027
*1
PR mode
OFF : 8-byte serial output (fixed in 8 characters)
ON : 16-byte serial output (1 to 16 characters)
Head character
End character
*
Operation starts when changed from X000=OFF to ON.
TTT
T: Operation cycle
or interrupt time
Drive input X000
Data Y007 to Y000
Strobe Y010
Execution busy flag Y011
Execution complete flag M8029
* If H00 (NUL code) exists in the data (in 16 characters), one character before H00 (NUL code) is the end character.