899
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
B Instruction Execution Time
B-1 Basic Instruction Execution Time
31
FNC275-FNC279
Data
Transfer 3
32
FNC280-FNC289
High Speed
Processing 2
33
FNC290-FNC299
Extension File
Register
34
FNC300-FNC305
FX
3U
-CF-ADP
35
SFC•STL
Programming
36
Interrupt
Function
37
Special Device
38
Error Code
A
Version Up
Information
B
Execution Times
•FX3G PLCs (Standard mode)
Instruction
Execution time in ON status (µs) Execution time in OFF status (µs)
Remarks
16-bit instruction 32-bit instruction 16-bit instruction 32-bit instruction
Contact instructions
LD 0.21
1.34 µs in 2-step instruction
*1
1.34 µs in 3-step instruction
*3
LDI 0.21
1.34 µs in 2-step instruction
*1
1.34 µs in 3-step instruction
*3
LDP 2.32 2.28
3-step instruction
2.4 µs in execution in ON status
*3
2.36 µs in execution in OFF status
*3
LDF 2.36 2.32
3-step instruction
2.44 µs in execution in ON status
*3
2.4 µs in execution in OFF status
*3
AND 0.2
1.16 µs in 2-step instruction
*1
1.2 µs in 3-step instruction
*3
ANI 0.2
1.16 µs in 2-step instruction
*1
1.2 µs in 3-step instruction
*3
ANP 2.36 2.32
3-step instruction
2.48 µs in execution in ON status
*3
2.44 µs in execution in OFF status
*3
ANF 2.4 2.36
3-step instruction
2.48 µs in execution in ON status
*3
2.44 µs in execution in OFF status
*3
OR 0.21
1.28 µs in 2-step instruction
*1
1.32 µs in 3-step instruction
*3
ORI 0.21
1.28 µs in 2-step instruction
*1
1.32 µs in 3-step instruction
*3
ORP 2.36 2.32
3-step instruction
2.48 µs in execution in ON status
*3
2.44 µs in execution in OFF status
*3
ORF 2.4 2.36
3-step instruction
2.48 µs in execution in ON status
*3
2.44 µs in execution in OFF status
*3
Connection instructions
ANB 0.2
ORB 0.2
MPS 0.21
MRD 0.2
MPP 0.17
INV 0.17
MEP 1.52
MEF 1.6
Output instructions
OUT Y,M 0.21
1.2 µs in 2-step instruction
*2
1.2 µs in 3-step instruction
*3
OUT S 1.25 1.25
OUT T K 2.41 2.16
T246 to T319
2.69 µs in execution in ON status
2.04 µs in execution in OFF status