895
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-3 Version Upgrade History
31
FNC275-FNC279
Data
Transfer 3
32
FNC280-FNC289
High Speed
Processing 2
33
FNC290-FNC299
Extension File
Register
34
FNC300-FNC305
FX
3U
-CF-ADP
35
SFC•STL
Programming
36
Interrupt
Function
37
Special Device
38
Error Code
A
Version Up
Information
B
Execution Times
Appendix A-3-2 Version check
Special data register D8001 (decimal) contains information for determining the PLC version. Or for the FX3G, FX3U
and FX3UC PLCs, the PLC version can be verified in "PLC Status" within the display module.
→ For the operating procedure of the display module,
refer to the Hardware Edition Manual of the PLC to be checked.
Appendix A-3-3 Version upgrade history [FX3G]
→ For the manufacturer’ serial number check method, refer to Appendix A-3-1.
Appendix A-3-4 Version upgrade history [FX3U]
→ For the manufacturer’ serial number check method, refer to Appendix A-3-1.
Version
Manufacturer’s
serial number
Contents of version upgrade
Ver.1.00
86****
(June, 2008)
First product
Ver.1.10
8X****
(October, 2008)
• Supports following instructions:
FLT(FNC49), VRRD(FNC85), VRSC(FNC86), ECMP(FNC110), EMOV(FNC112),
EADD(FNC120), ESUB(FNC121), EMUL(FNC122), EDIV(FNC123),
ESQR(FNC127), INT(FNC129), IVCK(FNC270), IVDR(FNC271), IVRD(FNC272),
IVWR(FNC273)
• Supports connection of FX
3G-8AV-BD, FX3G-2AD-BD, and FX3G-1DA-BD.
• Supports connection of display module (FX
3G-5DM).
• Supports the floating point operation function.
• Supports the inverter communication function.
• Supports the pulse width/pulse period measurement function.
Ver.1.20
96****
(June, 2009)
• Supports connection of following analog special adapters:
-FX
3U-3A-ADP
• Supports the hardware error function of FX
3U-4DA-ADP.
Version
Manufacturer’s
serial number
Contents of version upgrade
Ver.2.20
55****
(May, 2005)
First product (supporting the functions described as "Ver.2.20 or later" in this manual)
Corresponds to FX
3UC PLC Ver. 2.20.
Ver. 2.30
5Y****
(November, 2005)
• Adding the following instructions and function up.
- Adding MEP and MEF instructions
- Function up of MUL (FNC 22), DIV (FNC 23), and RS2 (FNC 87) instructions
Ver. 2.41
7Y****
(November, 2007)
• The baud rate "38400 bps" is supported in the RS and RS2 instructions, inverter
communication and computer link.
Ver. 2.61
97****
(July, 2009)
• Supports following 6 instructions:
FLCRT(FNC300), FLDEL(FNC301), FLWR(FNC302), FLRD(FNC303),
FLCMD(FNC304), FLSTRD(FNC305)
• Supports connection of following special adapters:
-FX
3U-3A-ADP
-FX
3U-CF-ADP
• Supports the hardware error function of FX
3U-4DA-ADP.
• Customer keyword / permanent PLC lock is supported.
D8001
PLC type and
version
2 4 1 0 0
Version information (Example: Ver. 1.00)
PLC type (Example: 24 = FX
2N
/FX
2NC
/FX
3U
/FX
3UC
PLC)