381
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
13 High Speed Processing – FNC 50 to FNC 59
13.10 FNC 59 – PLSR / Acceleration/Deceleration Setup
11
FNC30-FNC39
Rotation and
Shift
12
FNC40-FNC49
Data Operation
13
FNC50-FNC59
High Speed
Processing
14
FMC60-FNC69
Handy
Instruction
15
FNC70-FNC79
External FX I/O
Device
16
FNC80-FNC89
External FX
Device
17
FNC100-FNC109
Data
Transfer 2
18
FNC110-FNC139
Floating Point
19
FNC140-FNC149
Data
Operation 2
20
FNC150-FNC159
Positioning
Control
2. 32-bit operation (DPLSR)
Pulses are output from the output (Y) by the specified number [ +1, ] with acceleration/deceleration
to the maximum frequency [ +1, ] for the time [ +1, ](ms).
[ +1, ]: Maximum frequency (Hz)
- When special high speed output adapters are used
Allowable setting range: 10 to 200,000 (Hz)
- When the FX
3G/FX3U/FX3UC PLC main unit is used
Allowable setting range: 1 to 100,000 (Hz)
[ +1, ]: Total number of output pulses (PLS)
Allowable setting range
FX
3G : 110 to 2,147,483,647 (PLS)
FX
3U/FX3UC : 1 to 2,147,483,647 (PLS)
[ +1, ]: Acceleration/deceleration time (ms)
Allowable setting range: 50 to 5000 (ms)
: Pulse output number
Allowable setting range: Y000, Y001
3. Pulse output specifications
• Simple positioning (with the acceleration/deceleration function)
The operation pattern is as shown below:
• Output processing
The pulse output is controlled by the dedicated hardware regardless of the operation cycle.
• Data change while the instruction is executed
Even if operands are overwritten while the instruction is executed, such changes are not reflected immediately. The
changes become valid the next time the instruction is driven.
D
S
2
S
2
S
1
S
1
S
3
S
3
FNC 59
DPLSR
Maximum
frequency
(HZ)
Total
number
of output
pulses
(PLS)
Acceleration/
deceleration
time
(ms)
Output
number
(Y000,
Y001)
S
1
D
S
2
S
3
Command
input
S
1
S
1
S
2
S
2
S
3
S
3
D
Maximum frequency (Hz)
16-bit operation: 10 to 32767 Hz
32-bit operation: 10 to 200,000 Hz
Pulse frequency (Hz)
Total number of output pulses
(PLS)
S
1
S
2
50 to 5000ms
Acceleration/
deceleration time
S
3
50 to 5000ms
Acceleration/
deceleration time
S
3
16-bit operation
: 110 to 32767 (PLS)FX
3G
FX
3U
/FX
3UC
: 1 to 32767 (PLS)
FX
3G
32-bit operation
: 110 to 2,147,483,647 (PLS)
FX
3U
/FX
3UC
: 1 to 2,147,483,647 (PLS)