FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
14 Handy Instruction – FNC 60 to FNC 69
14.10 FNC 69 – SORT / SORT Tabulated Data
• The data table configuration is explained in an example in which the sorting source data table has 3 lines and 4
columns (m1 = K3, m2 = K4). For the sorting result data table, understand as .
• When the command input turns ON, data sorting is started. Data sorting is completed after "m1" scans, and the
instruction execution complete flag M8029 is set to ON.
→ For the instruction execution complete flag use method, refer to Subsection 6.5.2.
2. Operation examples
When the instruction is executed with "n = K2 (column No. 2)" and "n = K3 (column No. 3) for the following sorting
source data, the operations shown below are acquired.
It is recommended to put a serial number such as a control number in the first column so that the original line number
can be estimated based on the contents.
Sorting source data
1) Sorting result when the instruction is executed with "n = K2 (column No. 2)"
Column No.
Number of groups (m2 = K4)
1 2 3 4
Line No. Control number Height Weight Age
Number of
data
(m1 = 3)
1
+3 +6 +9
2
+1 +4 +7 +10
3
+2 +5 +8 +11
Column No. Number of groups (m2 = K4)
1 2 3 4
Line No. Control number Height Weight Age
Number of
data
(m1 = 5)
1
+ 5 + 10 + 15
1 150 45 20
2
+ 1 + 6 + 11 + 16
2 180 50 40
3
+ 2 + 7 + 12 + 17
3 160 70 30
4
+ 3 + 8 + 13 + 18
4100208
5
+ 4 + 9 + 14 + 19
5 150 50 45
Column No. 1 2 3 4
Line No. Control number Height Weight Age
1
+ 5 + 10 +15
4100208
2
+ 1 + 6 + 11 + 16
1 150 45 20
3
+ 2 + 7 + 12 + 17
5 150 50 45
4
+ 3 + 8 + 13 + 18
3 160 70 30
5
+ 4 + 9 + 14 + 19
2 180 50 40
D
1
S
D
1
D
S
S S S
S
S S S
S S S S
S S S S
S S S S
S S S S
S S S S
S S S S
D D D D
D D D D
D D D D
D D D D
D D D D