Mitsubishi Electronics FX3G Video Gaming Accessories User Manual


 
194
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
7 Basic Instruction
7.5 LDP, LDF, ANDP, ANDF, ORP, ORF
Cautions
1. Cautions when LDP, LDF, ANDP, ANDF, ORP, or ORF instruction programmed in a same step is
executed two or more times within one operation cycle
When LDP, LDF, ANDP, ANDF, ORP or ORF instruction programmed in a same step is executed two or more times
within one operation cycle, the following operation results:
Programs executed two or more times
Program between FOR and NEXT instructions
Program which executes a same subroutine program from two or more
CALL instructions during one operation cycle
Program which jumps to a label (P) in a smaller step number by CJ
instruction
Operation
1) When a device turns ON from OFF
1st time: LDP, ANDP or ORP instruction turns ON.
2nd time and later: When the device status is same as the time when the instruction was executed last, the
instruction turns OFF.
2) When a device turns OFF from ON
1st time: LDF, ANDF or ORF instruction turns ON.
2nd time and later: When the device status is same as the time when the instruction was executed last, the
instruction turns OFF.
2. Cautions on write during RUN
1) Instructions for falling edge pulse
When write during RUN is completed for a circuit including an instruction for falling edge pulse (LDF, ANDF, or
ORF instruction), the instruction for falling edge pulse is not executed without regard to the ON/OFF status of the
target device of the instruction for falling edge pulse.
When write during RUN is completed for a circuit including an instruction for falling edge pulse (PLF instruction),
the instruction for falling edge pulse is not executed without regard to the ON/OFF status of the operation
condition device.
It is necessary to set to ON the target device or operation condition device once and then set it to OFF for
executing the instruction for falling edge pulse.
2) Instructions for rising edge pulse
When write during RUN is completed for a circuit including an instruction for rising edge pulse, the instruction for
rising edge pulse is executed if a target device of the instruction for rising edge pulse or the operation condition
device is ON.
Target instructions for rising edge pulse: LDP, ANDP, ORP, and pulse operation type applied instructions (such
as MOVP)
*1. PLS instruction is not executed.
Contact ON/OFF status
(while write during RUN is executed)
Instruction for rising edge pulse Instruction for falling edge pulse
OFF Not executed Not executed
ON
Executed
*1
Not executed
X000
FNC 08
FOR
K
FNC 09
NEXT