13.7 FNC 56 – SPD / Speed Detection
11
FNC30-FNC39
Rotation and
Shift
12
FNC40-FNC49
Data Operation
13
FNC50-FNC59
High Speed
Processing
14
FMC60-FNC69
Handy
Instruction
15
FNC70-FNC79
External FX I/O
Device
16
FNC80-FNC89
External FX
Device
17
FNC100-FNC109
Data
Transfer 2
18
FNC110-FNC139
Floating Point
19
FNC140-FNC149
Data
Operation 2
20
FNC150-FNC159
Positioning
Control
Explanation of function and operation
1. 16-bit operation (SPD)
The input pulse is counted only for × 1 ms. The measured value is stored in , the present value is
stored in +1, and the remaining time is stored in +2 (ms).
By repeating this operation, the measured value will store the pulse density (which is proportional to the
rotation speed).
1) Timing chart
2) The measured value is in proportion to the number of rotations as shown below:
S
1
S
2
D
D
D
D
FNC 56
SPD
S
1
D
S
2
Command
input
Measured
value
The command contact is set to ON.
Command
input
S
1
D
+ 1 counts "OFF
ON" operation of .
ms later, the counting result is stored to .
Accompanied by this operation, +1 is reset, and
then counting of the "OFF
ON" operation of is
started again.
S
1
D
S
2
D
D
S
1
+ 2 is used to measure the remaining time.
D
Remaining time (ms)
D
+2
Counting time
ms
S
2
Counting time
ms
S
2
Current value
D
+1
ms
S
2
D
N(rpm)
Input X000
Proximity switch
"n" pulses/rotation
N =
60
nt
× 10 (r/min)
3
t: Measurement time duration specified as (ms)
S2
D