25. Block Data Operation – FNC190 to FNC199
FNC190 to FNC199 provide instructions for adding, subtracting and comparing block data.
FNC No. Mnemonic Symbol Function Reference
190 – –
191 – –
192 BK+ Block Data Addition Section 25.1
193 BK– Block Data Subtraction Section 25.2
194 BKCMP=
Block Data Compare =
Section 25.3
195 BKCMP>
Block Data Compare >
Section 25.3
196 BKCMP<
Block Data Compare <
Section 25.3
197 BKCMP<>
Block Data Compare ≠
Section 25.3
198 BKCMP<=
Block Data Compare ≤
Section 25.3
199 BKCMP>=
Block Data Compare ≥
Section 25.3
nDS2S1BK+
nDS2S1BK-
nDS2S1BKCMP=
S
1
S
2
nDS2S1BKCMP>
S
1
S
2
nDS2S1BKCMP<
S
1
S
2
nDS2S1
BKCMP<>
S
1
S
2
nDS2S1
BKCMP<=
S
1
S
2
nDS2S1
BKCMP>=
S
1
S
2