345
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
13 High Speed Processing – FNC 50 to FNC 59
13.3 FNC 52 – MTR / Input Matrix
11
FNC30-FNC39
Rotation and
Shift
12
FNC40-FNC49
Data Operation
13
FNC50-FNC59
High Speed
Processing
14
FMC60-FNC69
Handy
Instruction
15
FNC70-FNC79
External FX I/O
Device
16
FNC80-FNC89
External FX
Device
17
FNC100-FNC109
Data
Transfer 2
18
FNC110-FNC139
Floating Point
19
FNC140-FNC149
Data
Operation 2
20
FNC150-FNC159
Positioning
Control
Program example
n=Three outputs (Y020, Y021 and Y022) are set to ON in turn repeatedly.
Every time an output is set to ON, eight inputs in the 1st, 2nd and 3rd columns are received in turn repeatedly, and
stored to M30 to M37, M40 to M47 and M50 to M57 respectively.
In this program example, the FX
3U series main unit (sink input/sink output) is used. For writing details, refer to the
following manuals of the PLC used.
→ FX
3G Hardware Edition
→ FX
3U Hardware Edition
→ FX
3UC Hardware Edition
X021
M 51
X022
M 52
X023
M 53
X024
M 54
X025
M 55
X026
M 56
X027
M 57
M 50M 40
COM
Y020Y021Y022Y023Y024Y025Y026Y027
S/S X020X021X022X023X024X025X026X027
X021
X022
X023 X024 X025 X026X027
M 41
M 42
M 43
M 44
M 45
M 46
M 47
M 31
M 32
M 33
M 34
M 35
M 36
M 37
M 30
Diode
0.1A(50V)
2nd
column
1st
column
PLC
3rd
column
Diode
0.1A(50V)
Diode
0.1A(50V)
M0
Y020
[1] [4]
Y021
[2] [5]
[3] [6]
Y022
20ms
M8029 (execution
complete)
1st column input is received.
2nd column input is received.
3rd column input is received.
M0
FNC 52
MTR
X020 Y020 M 30 K 3
S D
1
D
2
n
Number
of
columns
Input
number
Output
number
ON
output
destination
Sink input
Sink output
0V
24V