896
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-3 Version Upgrade History
Appendix A-3-5 Version upgrade history [FX3UC]
*1. The FX3UC-32MT-LT supports Ver.2.41 from the manufacturer's serial number "7X****" (October 2007).
*2. The FX
3UC-32MT-LT-2 PLC is due to be upgraded later.
→ For the manufacturer’ serial number check method, refer to Appendix A-3-1.
Version
Manufacturer’s
serial number
Contents of version upgrade
Ver.1.00
41****
(January, 2004)
First product
Ver.1.20
44****
(April, 2004)
Supports connection of following special analog adapters:
-FX
3U-4AD-ADP
-FX
3U-4DA-ADP
Ver.1.30
48****
(August, 2004)
• Supports connection of following special analog adapters:
-FX
3U-4AD-PT-ADP
-FX
3U-4AD-TC-ADP
• Supports connection of following special function block:
-FX
3UC-4AD
• Supports following 3 instructions:
- SCL2 (FNC269), RWER (FNC 294), and INITER (FNC 295)
• Adds function of following instruction:
- DVIT (FNC151)
Ver.2.20
55****
(May, 2005)
Supports the functions described as "Ver.2.20 or later" in this manual.
• Supports following 28 instructions:
ZPUSH(FNC102), ZPOP(FNC103), WSUM(FNC140),WTOB(FNC141),
BTOW(FNC142),UNI(FNC143), DIS(FNC144), SORT2(FNC149), TBL(FNC152),
COMRD(FNC182), DUTY(FNC186), BK+(FNC192), BK-(FNC193),
BKCMP=(FNC194), BKCMP>(FNC195), BKCMP<(FNC196),
BKCMP<>(FNC197), BKCMP<=(FNC198), BKCMP>=(FNC199), STR(FNC200),
VAL(FNC201), INSTR(FNC208), FDEL(FNC210), FINS(FNC211),
DABIN(FNC260), BINDA(FNC261), RBFM(FNC278), WBFM(FNC279)
• Adds function of following 5 instructions:
SPD(FNC 56), DSZR(FNC150), DVIT(FNC151), ZRN(FNC156), PLSV(FNC157),
HCMOV(FNC189)
• Supports connection of FREQROL-F700/A700 inverters supporting following 5 instructions:
IVCK (FNC270), IVDR (FNC271), IVRD (FNC272), IVWR (FNC273), and IVBWR (FNC274)
• Adds second entry code
(when GX Developer SW8.23Z (Ver. 8.23Z or later) is used).
• Supports BFM initial value setting function
(when GX Developer SW8.23Z (Ver. 8.23Z or later) is used).
• Mitigates restriction in writing during RUN
(when GX Developer SW8.23Z (Ver. 8.23Z or later) is used).
- Number of steps which can be changed by one-time write during RUN is changed.
127 steps → 256 steps
- Handling of circuit blocks which can be changed by one-time write during RUN is changed.
Program of continuous circuit blocks having 127 steps or less →
Program of circuit blocks having 256 steps or less in total
Ver. 2.30
5Y****
(November, 2005)
Adding the following instructions and function upgrade.
Adding MEP and MEF instructions
Function upgrade of MUL (FNC 22), DIV (FNC 23), and RS2 (FNC 87) instructions.
Ver. 2.41
79****
*1
(September, 2007)
•FX
3UC-MT/D, DSS (First product)
• The baud rate "38400 bps" is supported in the RS and RS2 instructions, inverter
communication and computer link.
Ver. 2.53
84****
(April, 2008)
FX
3UC-32MT-LT-2 (First product)
Ver. 2.61
*2
97****
(July, 2009)
• Supports following 6 instructions:
FLCRT (FNC300), FLDEL (FNC301), FLWR (FNC302), FLRD (FNC303),
FLCMD (FNC304), FLSTRD (FNC305)
• Supports connection of following special adapters:
-FX
3U-3A-ADP
-FX
3U-CF-ADP
• Supports the hardware error function of FX
3U-4DA-ADP.
• Customer keyword / permanent PLC lock is supported.