Agilent Technologies E8285A Video Games User Manual


 
437
Chapter 4, Description of Fields
Fields
TX Power
Transmitter Power measures RF power at the RF IN/OUT port.
Operating Considerations
Only the RF IN/OUT port can be used for measuring TX Power. When the Input
Port
is set to Ant, four dashes (- - - -) appear in place of digits for this
measurement.
Use the Spectrum Analyzer to measure low-level RF power (
200 mW) at the
ANTENNA IN port.
CAUTION: Connecting a signal of >200 mW to the ANTENNA IN port can cause instrument
damage (although internal protection circuits can typically withstand a short-duration
signal of 1 or 2 Watts). If the overpower circuit is triggered (signified by a warning
message at the top of the screen), remove the signal from the ANTENNA IN port, and
press the Meas reset key or turn the Test Set off and on to reset it.
See Also
Input Port
field description, on page 278
TX Power
field description, on page 437
TX Pwr Zero
field description, on page 440
Screens Where Field is Present
ADJACENT CHANNEL POWER
ANALOG MEAS
DUPLEX TEST
AF ANALYZER
RF ANALYZER
RF GENERATOR
TX TEST