Agilent Technologies E8285A Video Games User Manual


 
182
S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields
Band Class
The Band Class field is displayed on the CDMA CALL CONTROL screen when
the
"Protocol" field on page 346 is set to TIA/EIA-95B and the "RF Chan Std"
field on page 365
is set to USER-DEF. This field allows entry of the
BAND_CLASS parameter.
The range of values that can be entered in this field is 0 to 4.
GPIB Example
“DISP CCNT;CDMA:CELL:BCL 0“
sets the BAND_CLASS parameter to 0.
Operating Considerations
The value entered in the Band Class field affects Test Set operation only when the
"Protocol" field on page 346 is set to TIA/EIA-95B and the "RF Chan Std" field on
page 365
is set to USER-DEF.
The BAND_CLASS parameter, which affects forward channel messages, is a
function of Protocol and RF Chan Std field settings.
When the RF Chan Std field is set to USER-DEF (user defined) the user is
expected to select one of the five available values.
If BAND_CLASS 0, 2, or 3 is selected:
•The
"Nom Pwr Ext" field on page 312
field is removed from the CDMA CELL SITE
CONFIGURATION screen, and
The offset power used to calculate
"Ideal Mobile Power" field on page 273
is set to
-73, and
The Neighbor List Message is sent on the Paging channel (not the Extended Neighbor
List Message), and
•The BASE_CLASS field in the System Parameters message on the Paging channel is
set to 0 (Public Macrocellular System)
If BAND_CLASS 1 or 4 is selected:
•The
"Nom Pwr Ext" field on page 312
field is displayed on the CDMA CELL SITE
CONFIGURATION screen, and
The offset power used to calculate "Ideal Mobile Power" field on page 273 is set to
-76, and
The Extended Neighbor List Message is sent on the Paging channel (not the Neighbor
List Message), and
•the BASE_CLASS field in the System Parameters message on the Paging channel is
set to 1 (Public PCS System)