Agilent Technologies E8285A Video Games User Manual


 
180
S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields
Average Power measurements are made using a factory-calibrated power
detector.The detector measures power during the time that power control groups
are gated on. Each Average Power measurement is computed from data taken
during a 10 ms (one-half of one traffic frame) sampling period, ensuring that at
least one out of the eight available power control groups in the half-frame will be
gated on, even if the transmit data rate is 1200 bps.
For example, if the data rate is 9600 bps (full-rate) average power will be
measured during all eight available power control groups. If the data rate is 1200
bps, Average Power will be measured during only one power control group. (The
Test Set is able to determine the pseudo-random positioning of the power control
groups that are gated on). The benefit of this measurement process is that
measurement results will be consistent across all possible transmit data rates.
Use the “TRIG” command to trigger Average Power measurements when using
single trigger mode. (The command “TRIG:AST ‘Arm’” will not trigger Average
Power measurements).
See Also
"Chan Power" on page 197
“Zeroing Average Power Measurements” in the Calibrating the Test Set chapter of
the E8285A Application Guide
Screens Where Field is Present
CDMA CALL CONTROL
CDMA TRANSMITER POWER RANGE TEST
CDMA CELLULAR MOBILE TRANSMITTER TEST