Agilent Technologies E8285A Video Games User Manual


 
374
S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields
Run
Selecting this field runs the IBASIC program.
Screens Where Field is Present
TESTS (IBASIC Controller)
Run Test
Selecting this field loads and runs the test chosen in the Select Procedure
Filename:
field.
Screens Where Field is Present
TESTS (Main Menu, Execution Conditions, Printer Setup)
SAT
This field allows entry of the SAT color code for CDMA to analog handoffs.
5970Hz
6000Hz
6030Hz
GPIB Example
“CDMA:CALL:AHAN:SAT’6000Hz’“
sets the SAT field to 6000 Hz.
Operating Considerations
During a CDMA-to-analog handoff, the Test Set sends a message to the mobile
station assigning this supervisory audio tone to the analog call.
A CDMA-to-analog handoff attempt will occur when the Execute field on the
CDMA CALL CONTROL screen is selected.
Range of values: 0 through 2
Screens Where Field is Present
CDMA CALL CONTROL