Agilent Technologies E8285A Video Games User Manual


 
334
S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields
Pilot Inc
This field allows entry of the increment between the pilot PN offsets of the
Neighbor Set pilots.
When a mobile station finds CDMA service from the Test Set it is assigned seven
Neighbor Set pilots in the Neighbor List Message. The Test Set assigns the first
Neighbor Set pilot to the same PN offset as Sector B (this value is displayed on
the CDMA Generator Control screen).
To complete the list, six additional Neighbor Set pilots are assigned equally-
spaced PN Offsets, beginning with 15 times the Pilot Inc field setting. For
example, if Pilot Inc is set to 10, the entire Neighbor Set would consist of the
following pilots: 150, 160, 170, 180, 190, and 200. All values will be congruent to
modulo 512, which is the number of unique values allowed for the pilot offset
index.
GPIB Example
“DISP CCON;CDMA:CELL:CONFigure:PINcrement 12“
sets the Pilot Inc field to 12.
Operating Considerations
This field affects the range of PN Offsets over which the mobile station has to
search to monitor power levels of pilots in the Neighbor list
Range of values: 1 through 15
Screens Where Field is Present
CDMA CELL SITE CONFIGURATION