Agilent Technologies E8285A Video Games User Manual


 
395
Chapter 4, Description of Fields
Fields
SID MSB
This field is used to set the system identification number (SID) of the Test Set.
The
SID field is an immediate action field. If the field is selected and changed, the
signaling message(s) being sent on the forward control channel are immediately
changed. No change occurs to the current state (that is, active, register, page,
access, connect) of the Call Processing Subsystem.
This field is used to set the system identification number (SID) of the Test Set.
The :SIDentify command is used to control this field.
The query form of the command (that is, :SIDentify?) can be used to determine
the current system identification number (SID) setting.
Syntax
:SIDentify <integer number>
:SIDentify?
Example
OUTPUT 714;"CALLP:SID 231"
OUTPUT 714;"CALLP:SID?"
ENTER 714;Sid_number
Screens Where Field is Present
CALL CONTROL