Chapter 4, Description of Fields
Fields
GPIB Example
“STATus:CDMA2:EVENt?”
queries the CDMA_2 status event register. If bit 5 is set, the last gated power test
passed. If bit 4 is set, the last gated power test failed.
FER
This field displays the current frame error rate (FER) measured by the Test Set. A
Service Option 2 (mobile station data loopback) call must be connected before
running an FER test.
A measurement result will be displayed at the end of a test if Display Interim
Results is
No. (The Passed, Failed, or Max Frames annunciator will light
when a test is done.) Measurement results will be displayed continuously, and
queries will be returned based on interim results if Display Interim Results is
Yes.
GPIB Example
“DISP CRXT;MEASure:CDManalyzer:FERasure?“
queries the currently displayed FER measurement result.
Operating Considerations
To measure FER, the mobile station must be on a traffic channel and looping data
back. The
Connected and Svc Opt 2 annunciators are lit when the mobile
station is looping data back.
The CDMA Status Register provides status bits for the Passed, Failed, and Max
Frames Test Status indicators.
See Also
Meas Cntl
field description, on page 295
Screens Where Field is Present