Add Intcpt
This field is used to enter the parameter ADD_INTERCEPT. Refer to ANSI TIA/
EIA-95-B for additional details.
This field is displayed only when TIA/EIA-95B is selected in the
"Protocol" field
on page 346
.
GPIB Example
“DISP CMOB;CDMA:MOB:PARM:IADD 8”
enters 8 in the Add Intcpt field.
Operating Considerations
This field setting, along with the "Soft Slope" field on page 400, modifies the way
that the mobile station manages pilot sets. Refer to the formula found in the field
description for
"Expected T_Add" field on page 254. These fields also affect the
conditions which require the mobile station to send a Pilot Strength Measurement
Message.
See Also
Expected T_Add
field description, on page 254
Expected T_Drop
field description, on page 255
Add Intcpt
field description, on page 154
Drop Intcpt
field description, on page 237
Addr
This field is used to enter the instrument’s remote address. For GPIB instruments,
enter the full 3-digit address (such as 704).
Screens Where Field is Present