Agilent Technologies E8285A Video Games User Manual


 
308
S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields
MS FER Report Interval
This field sets the number of frames the mobile station will count before reporting
frame error rate (FER) when the
by # frames field is On.
GPIB Example
“DISP CFER;CDMA:MOBile:FERasure:REPort:INTerval’160 FRAMES’“
sets the mobile station’s FER report interval to 160 frames.
Operating Considerations
This setting may affect FER measurement speed and will affect the display rate of
the
MS FER Report field.
Screens Where Field is Present
CDMA MOBILE REPORTED FER
MS ID
The MS ID field determines how the Test Set identifies a mobile station for
paging. Depending on the Protocol field choice, some combination of the
following modes are available, with
Auto as the default.
Auto - The Test Set will obtain the mobile station’s identification through mobile
station registration, either at mobile station power-on or when the Register field is
selected.
Phone Num -Allows entry of a 10-digit phone number that identifies the mobile
station, overriding any value for phone number that the test set may have obtained
during mobile station power-on registration. The mobile station must be NON-
SLOTTED to use this MS ID mode. This choice is displayed when IS-95 is selected in
the
"Protocol" field on page 346
.
MIN - Allows entry of MIN, a 9-digit hexadecimal string normally derived from the
phone number, overriding any value for MIN that the test set may have obtained during
mobile station power-up registration. The mobile station must be NON-SLOTTED to
use this MS ID mode. This choice is displayed when IS-95 is selected in the
"Protocol"
field on page 346
.
IMSI - Allows entry of IMSI, consisting of MCC, MNC, and MSIN. This choice is
displayed when IS-95A, TSB-74, KorPCS, ARIB T53, or J-STD-008 is selected in the
"Protocol" field on page 346.