Agilent Technologies E8285A Video Games User Manual


 
240
S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields
NOTE: Use the CALL CONTROL screen to set the DSAT sequence. Using the SIGNALING
ENCODER screen to change the DSAT will cause dropped calls.
The DSAT entered in this field is used in digital to analog handoffs.
GPIB Example
“CDMA:CALL:AHAN:DSAT’0 2556CB’“
sets the DSAT field to 0 2556CB.
See Also
Execute (Handoff)
field description, on page 250
Screens Where Field is Present
CALL CONTROL
CDMA CALL CONTROL
DSAT/DST (hex)
The DSAT/DST (hex) field is displayed only when the System Type field is set
to
NAMPS and the Display field is set to NMeas.
The DSAT/DST field displays the received
DSAT/DST sequence from the mobile
station on the reverse voice channel. The received sequence is displayed in
hexadecimal and can be checked against the DSAT value displayed in the DSAT
right-hand DSAT field. Four dashes (----) indicate no carrier is present to measure.
A numeric value would only be displayed when the Test Set’s
Connected
annunciator is lit (connected state).
The :DSAT:MEASurement? query command is used to query the contents of the
left-hand subfield.
There is no command form of the :MEASurement? query.
Syntax
:DSAT:MEASurement?
Example
OUTPUT 714;"CALLP:NAMP:DSAT:MEASurement?"
ENTER 714;MEASured_dsat$
Screens Where Field is Present
CALL CONTROL