Agilent Technologies E8285A Video Games User Manual


 
274
S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields
IF Filter
This field selects the desired IF filter bandwidth for modulated signals being
analyzed.
Screens Where Field is Present
TX TEST
DUPLEX TEST
RF ANALYZER
If Unit-Under-Test Fails
This field selects what happens if the measured results do not meet criteria for
passing the current test. The underlined entry is the active choice.
Continue continues with testing even though a test in the test sequence fails to meet
its test specification limits. When this occurs, an error is listed on the test-results print-
out, is displayed on the CRT, or both.
Stop stops the test when a failure occurs and requires operator intervention before test-
ing proceeds.
Screens Where Field is Present
TESTS (Execution Conditions)
Init Power
This field allows entry of the initial power offset for system access (INIT_PWR).
GPIB Example
“DISP CCON;CDMA:CELL:CONFigure:INITial:POWer 0“
sets INIT_PWR to 0.
Operating Considerations
This field specifies a correction factor the mobile station adds to the estimated
open-loop output power for setting the power level of the first (initial) access
probe in an access probe sequence.
Screens Where Field is Present
CDMA CELL SITE CONFIGURATION