Agilent Technologies E8285A Video Games User Manual


 
422
S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields
T_TDrop
This field allows entry of the handoff drop timer’s value (T_DROP).
GPIB Example
“DISP CMOB;CDMA:MOBile:TTDRop 2“
sets T_TDROP to 2.
Operating Considerations
When the Softer Handoff annunciator is lit, Sector A and Sector B are added
to the mobile station’s Active list. If either of these pilot’s signal strength falls
below
T_DROP, the mobile station starts its handoff drop timer, T_TDROP. If the
weaker pilot’s signal strength remains below
T_DROP and the timer expires, the
mobile station will send a Pilot Strength Measurement message to the Test Set.
The Test Set will display “To Drop” in the Status column of the CDMA Mobile
Reporting table for the Sector A or Sector B pilot that fell below T_Drop
(identified by PN Offsets). Refer to
table 18.
See Also
T_Drop
field description, on page 421
Screens Where Field is Present
CDMA MOBILE REPORTED PILOT STRENGTH
Test Name
This field displays the names of the tests available from the software package or
program currently selected. As you turn the knob, the
Test Name for the
corresponding step appears above the test’s
Description.
Screens Where Field is Present
TESTS (Order of Tests)
Table 18 Handoff Drop Timer Expiration Values
T_TDROP
Timer
Expiration
(seconds)
T_TDROP
Timer
Expiration
(seconds)