Agilent Technologies E8285A Video Games User Manual


 
378
S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields
Save/Recall
This field specifies which memory device the Test Set accesses when the save and
recall functions are used.
Internal is a section of internal RAM. RAM is also used for running IBASIC
programs, which may require you to delete the Save/Recall registers if the program is
very large.
Card is the front-panel MEMORY CARD slot. A Save/Recall Device is not
Present message is displayed if you try to save or recall an instrument setup when
a write-able memory card is not installed in the Test Set.
RAM refers to RAM disks that you can create on internal RAM. For information on
creating RAM disks, see “Memory Cards/Mass Storage” chapter of the This is part of
the same memory used when “internal” is specified, and may have to be erased when
loading very large IBASIC programs. A Save/Recall Device is not
initialized message is displayed if you try to save or recall an instrument setup
when a RAM disk has not been created.
Disk is used with external disk drives. The Mode field must be set to Control to
access the drive. Also, the GPIB address of the drive must be entered in the External
Disk Specification field of the TESTS (External Devices) screen.
Screens Where Field is Present
I/O CONFIGURE
SCM:
This field displays the decoded station class mark information received from the
mobile station on the reverse control channel in response to a forward control
channel message. The decoded SCM consists of: the mobile station power class
(Class I, II, or III), the transmission type (continuous/discontinuous), and the
transmission bandwidth (20 MHz or 25 MHz).
The
SCM: field is only displayed when the Display field is set to Data and a
reverse control channel message has been decoded.
Refer to the
"Display" field on page 223 for information on how to read
measurement results from this field.
Screens Where Field is Present
CALL CONTROL