Chapter 4, Description of Fields
Fields
NOTE: Decoder and Oscilloscope Interference: The AF autoranging function (Auto)
takes a small amount of time to determine the attenuation settings for the AF
Analyzer. If you are decoding an encoded signal, and your transmitter begins sending
encoded information the instant it transmits, the initial encoded information may not
be decoded during the autoranging process.
Use the Auto setting to establish the initial gain settings while the encoded signal is
first being decoded, and then select Hold during the decoding process to retain the
gain settings. The decoder should capture all encoded information the next time you
transmit the signal.
Screens Where Field is Present
AF ANALYZER
(Gen)-(Anl)
This field is used with the RF Offset field to specify the amount of frequency
offset between the RF Generator and RF Analyzer.
This field is not displayed when the
RF Display field is set to Chan (the offset is
automatically set when using channel tuning).
Screens Where Field is Present
CONFIGURE
Grid
This field is displayed only when Display is selected in the Controls field.
This field provides control of the CDMA GATED POWER display grid.
On displays dashed lines delineating the time scale on the X axis and the relative level
scale on the Y axis. .
Off erases the dashed lines, leaving only the mask and measurement trace information.
GPIB Example
“DISP CGP;CDMA:GPOWer:GRID ’On’“
turns off the display grid.
Screens Where Field is Present
CDMA GATED POWER