Agilent Technologies E8285A Video Games User Manual


 
407
Chapter 4, Description of Fields
Fields
SSDA
The :SSDA command is only available through the remote users interface. No
field is displayed for this function on the test set. The user can enter a valid value
into the Test Set along with other necessary shared secret data to avoid the SSD
Upd process at the start of testing to reduce testing time.
SSDA is the most significant 64-bits of the SSD value stored in the mobile station.
SSDA is entered as a 16-digit hexadecimal value.
The query form (that is, :SSDA?) can be used to query the current Test Set value.
Syntax
:SSDA <‘><16 character hex value><‘>
:SSDA?
Example
OUTPUT 714;"CALLP:AMPS:AUTH:SSDA ‘1234567890ABCDEF’"
OUTPUT 714;"CALLP:AMPS:AUTH:SSDA?"
ENTER 714;Ssda_val$
The :SSDA:NEW command is only available through the remote users interface.
No field is displayed for this function on the test set. This value can be used
during authentication to replace or query the SSD-A_NEW value in the Test Set.
The :SSDA:NEW value is the most significant 64-bits of the SSD value stored in
the mobile station. SSDA:NEW is entered as a 16-digit hexadecimal value.
The query form (that is, :NEW?) can be used to query the current Test Set value.
Syntax
:NEW <‘><16 character hex value><‘>
:NEW?
Example
OUTPUT 714;"CALLP:AMPS:AUTH:SSDA:NEW ‘1234567890ABCDEF’"
OUTPUT 714;"CALLP:AMPS:AUTH:SSDA:NEW?"
ENTER 714;Ssda_new_val$