Agilent Technologies E8285A Video Games User Manual


 
350
S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields
RAND
The 32-bit value entered in this field, Random Challenge Value, will be used by
the mobile station during authentication procedures. RAND is sent to the mobile
station on the Paging Channel Access Parameters Message.
GPIB Example
“CDMA:CELL:CONF:AUTH:RAND?”
queries the RAND field.
Screens Where Field is Present
CDMA AUTHENTICATION
RAND_A
RAND_A is the 16 most significant bits of RAND and is entered as a 4-digit
hexadecimal value. The mobile station stores and uses the most recent version of
RAND_A in the authentication process. RAND_A is user definable.
The :RAND:A command is used to control this field.
The query form (that is, :RAND:A?) can be used to query the current field value.
Syntax
:RANDA
:RANDA?
Example
OUTPUT 714;"CALLP:AMPS:AUTH:RAND:A ‘4F5A’"
OUTPUT 714;"CALLP:AMPS:AUTH:RAND:A?"
ENTER 714;Rand_val$
Screens Where Field is Present
AUTHENTICATION