Chapter 4, Description of Fields
Fields
Then, to measure maximum power, the Test Set sets Sector A power to -104 dBm/
BW, turns the Call Drop Timer “Off”, and sends “Always Up” power control bits
to the mobile station, using a procedure similar to the EIA/TIA IS-98 test
“Maximum RF Output Power”. An Average Power measurement is made, and the
Test Set is returned to closed loop power control mode.
See Also
Max Power
field description, on page 293
Min Power
field description, on page 296
Screens Where Field is Present
CDMA TRANSMITTER POWER RANGE TEST
Mobile Parm
These fields allow entry or display of a mobile station parameter identifier or
value.
MUX1_REV_1 through MUX1_REV_14
MUX2_REV_1 through MUX2_REV_25 (TSB-74 and J-STD-008 only)
MUX1_FOR_1 through MUX1_FOR_ 14
MUX2_FOR_1 through MUX2_FOR_26 (TSB-74 and J-STD-008 only)
PAG_1 through PAG_7
ACC_1 through ACC_8
LAYER2_RTC1 through LAYER2_RTC5
SYS_TIME
GPIB Example
“DISP CFER;CDMA:MOBile:PARM ‘MUX1_REV_1’“
identifies the mobile station parameter MUX1_REV_1.
“DISP CFER;CDMA:MOBile:PARM:VALue 0“
sets the mobile station’s MUX1_REV_1 parameter value to 0.
Operating Considerations
This field allows selection of a mobile station Parameter Identifier, and displays
the value of the selected parameter. If a call is connected and a value is entered, an
attempt will be made to write this value into the corresponding register in the
mobile station. This field is only valid for mobile stations that conform to the EIA/
TIA IS-95-A standard.
Screens Where Field is Present
CDMA MOBILE REPORTED FER