Agilent Technologies E8285A Video Games User Manual


 
418
S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields
System ID
This field allows entry of the system identification (SID).
GPIB Example
“DISP CCON;CDMA:CELL:CONFigure:SID 0“
sets the system identification of the simulated CDMA cell site to 0.
Operating Considerations
The mobile station stores the SID number it receives from the cell site and
compares it with its home SID/NID to determine if it is roaming.
Screens Where Field is Present
CDMA CELL SITE CONFIGURATION
System Type (Call Control)
This field is used to select the type of cellular system (AMPS, NAMPS, TACS,
JTACS, NTACS) to be simulated.
The
System Type field is an immediate action field. That is, whenever the
System Type field is changed, the change is reflected immediately in the
physical configuration of the Test Set. The analog control channel is immediately
de-activated, reconfigured, and then re-activated to reflect the change. This
change causes the Test Set to enter the ACTIVE state.
NOTE: If the Test Set is in the connected state (Connect annunciator is lit) and a change is made to
the System Type field, the connected state will be lost.
The :CSYStem command is used to control this field.
Syntax
:CSYStem <'><AMPS/NAMPS/TACS/JTACS/DCCH><'>
:CSYStem?
Example
OUTPUT 714;"CALLP:CSYS 'AMPS'"
OUTPUT 714;"CALLP:CSYS?"
ENTER 714;System_type$
Screens Where Field is Present
CALL CONTROL