Chapter 4, Description of Fields
Fields
Amplitude
This field sets the output power of the Test Sets’s transmitter (that is, the output
power of the Test Set’s RF Generator). See “RF Generator” in the GPIB
Command Syntax chapter of the E8285A Condensed Programming Reference
Guide for programming command syntax.
The :AMPLitude command is used to control this field.
To query the current setting of the amplitude field use the :AMPLitude?
command.
Syntax
:AMPLitude <real number> <units>
:AMPlitude?
Example
OUTPUT 714;"CALLP:AMPL -50 DBM"
OUTPUT 714;"CALLP:AMPL?"
ENTER 714;Ampl_val$
Operating Considerations
This is a priority control field. Accessing the RX TEST or TX TEST screen
overrides any changes made to this field in other screens.
If a microphone is connected, and the amplitude is set to
Off, keying the
microphone causes the amplitude to turn on to its previous level until the
microphone is no longer keyed.
See Also
"Atten Hold" on page 169
Screens Where Field is Present
DUPLEX TEST
RF ANALYZER
RF GENERATOR
RX TEST
SPECTRUM ANALYZER
CALL CONTROL
ANALOG MEAS