Agilent Technologies E8285A Video Games User Manual


 
245
Chapter 4, Description of Fields
Fields
The encoding to be used by mobile stations for the Octet encoding type is
unspecified in the IS-637 and TSB79 standards. While some mobile stations use
ASCII encoding, others may use a different encoding or may not implement the
Octet encoding type at all. Consequently, using ‘Octet’ encoding to send ASCII
User Data to a mobile station may cause the mobile station to display the message
using a different character set or not display a message at all.
See Also
User Data (ASCII or Hex)
field description, on page 443
Screens Where Field is Present
CDMA SHORT MESSAGE SERVICE
Enter ASCII Data
This field is displayed when the Message Data Mode is set to ASCII. It is used
to enter the message to be sent on the paging channel. You can use the default
message or enter your own message.
Operating Considerations
A maximum of 64 ASCII characters can be entered.
The default ASCII message is as follows:
ABCDEFGHIJKLMNOPQRSTUVWXYZ_01234
abcdefghijklmnopqrstuvwxyz#56789
Screens Where Field is Present
CDMA SHORT MESSAGE SERVICE
Enter Hex Data
This field is displayed when the Message Data Mode is set to Hex. It is used to
enter the message to be sent on the paging channel. You can use the default
message or enter your own message.
Operating Considerations
A maximum of 128 hex characters can be entered.
The default hex message is as follows:
4142434445464748494A4B4C4D4E4F50
5152535455565758595A5F3031323334