Agilent Technologies E8285A Video Games User Manual


 
370
S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp
Chapter 4, Description of Fields
Fields
RF Offset
This field is displayed when the RF Display field has Freq selected.
This field enables/disables the RF Generator
RF Analyzer frequency offset
specified in the
(Gen)-(Anl) field below it.
Operating Considerations
When an RF offset is used, changing the RF Generator’s frequency or RF
Analyzer’s tune frequency automatically alters the other setting. On screens where
both fields are not shown (such as the RX TEST and TX TEST screens), you will
not see the corresponding field change.
Screens Where Field is Present
CONFIGURE
RF Out
This field is used to indicate forward channel path losses or gains between the RF
IN/OUT port and the mobile station.
•Enter a positive value to indicate a gain (such as amplifier gain).
•Enter a negative value to indicate a loss (such as cable loss).
The RF Out
field is displayed only when RF Out is selected in the Output
Port
field.
GPIB Example
“CONF:OFL:RF:OUT -1”
enters a path loss of 1 dB between the RF IN/OUT port (output path only) and the
mobile station.
The value entered into this field is applied only when the
RF Level Offset
field is set to
On.
See Also
RF Level Offset
field description, on page 369
Screens Where Field is Present
CONFIGURE