Agilent Technologies E8285A Video Games User Manual


 
351
Chapter 4, Description of Fields
Fields
RAND_B
RAND_B is the 16 least significant bits of RAND and is entered as a 4-digit
hexadecimal value. The mobile station stores and uses the most recent version of
RAND in the authentication process. RAND_B is user definable.
The :RAND:B command is used to control this field.
The query form (that is, :RAND:B?) can be used to query the current field value.
Syntax
:RAND:B
:RAND:B?
Example
OUTPUT 714;"CALLP:AMPS:AUTH:RAND:B ‘4F5A’"
OUTPUT 714;"CALLP:AMPS:AUTH:RAND:B?"
ENTER 714;Rand_val$
Screens Where Field is Present
AUTHENTICATION
RANDSSD
This field contains random data for computation of SSD (Shared Secret Data).
RANDSSD is sent to the mobile station when an SSD Update is executed.
GPIB Example
“CDMA:CELL:CONF:AUTH:RANDS?”
queries the RANDSSD field.
See Also
"SSD Update" field on page 409
Screens Where Field is Present
CDMA AUTHENTICATION