Mitsubishi Electronics QD75P Video Game Controller User Manual


 
5 - 7
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
5.1.4 Setting items for positioning data
Positioning data must be set for carrying out any "major positioning control". The table
below lists the items to be set for producing the positioning data.
One to 600 positioning data items can be set for each axis.
For details of the major positioning controls, refer to Chapter 9 "Major Positioning
Control". For details of the individual setting items, refer to Section 5.3 "List of
positioning data".
Major positioning control Position control Other control
Positioning data
1-axis linear control
2/3/4-axis linear
interpolation control
1-axis fixed-feed control
2/3/4-axis fixed-feed control
2-axis circular interpolation
control
1 to 4 axis speed control
Speed-position switching
control
Position-speed switching
control
NOP instruction
Current value changing
JUMP instruction
LOOP
LEND
Independent
positioning
control
––
Continuous
positioning
control
––
Da.1
Operation
pattern
Continuous path
control
––
Da.2
Control system
Linear 1
Linear 2
Linear 3
Linear 4
Fixed-
feed 1
Fixed-
feed 2
Fixed-
feed 3
Fixed-
feed 4
Circular
sub
Circular
right
Circular
left
Forward
run speed 1
Reverse run
speed 1
Forward
run speed 2
Reverse run
speed 2
Forward
run speed 3
Reverse run
speed 3
Forward
run speed 4
Reverse run
speed 4
Forward
run
speed/
position
Reverse
run
speed/
position
Forward
run
position/
speed
Reverse
run
position/
speed
NOP
instruction
Current
value
changing
JUMP
instruction
LOOP LEND
Da.3
Acceleration time No.
––––
Da.4
Deceleration time No.
––––
Da.5
Axis to be
interpolated
: 2 axes
: 1/3/4 axes
–––
–––
Da.6
Positioning address/
movement amount
New
address
––
Da.7
Arc address
––
––
–––
Da.8
Command speed
–––
Da.9
Dwell time
(JUMP destination
positioning data No.)
JUMP
destination
positioning
data No.
––
Da.10
M code
(JUMP condition data No.)
JUMP
condition
data No.
No. of
LOOP to
LEND
repetitions
:Always set
:Set as required (Read "–" when not required.)
:Setting not possible
:Setting not required.
(This is an irrelevant item, so the set value will be ignored. If the value is the default value or within the setting range, there is no problem.)
:Two control systems are available: the absolute (ABS) system and incremental (INC) system.