Mitsubishi Electronics QD75P Video Game Controller User Manual


 
10 - 8
MELSEC-Q
10 HIGH-LEVEL POSITIONING CONTROL
10.3.2 Block start (normal start)
In a "block start (normal start)", the positioning data groups of a block are continuously
executed in a set sequence starting from the positioning data set in "
Da.12
Start data
No." by one start.
Section [2] shows a control example where the " block start data" and "positioning
data" are set as shown in section [1].
[1] Setting examples
(1) Block start data setting example
Axis 1 block
start data
Da.11
Shape
Da.12
Start data No.
Da.13
Special start
instruction
Da.14
Parameter
1st point 1: Continue 1 0: Block start
2nd point 1: Continue 2 0: Block start
3rd point 1: Continue 5 0: Block start
4th point 1: Continue 10 0: Block start
5th point 0: End 15 0: Block start
(2) Positioning data setting example
Axis 1 position-
ing data No.
Da.1
Operation pattern
1 00: Positioning complete
2 11: Continuous path control
3 01: Continuous positioning control
4 00: Positioning complete
5 11: Continuous path control
6 00: Positioning complete
1 block
1 block
10 00: Positioning complete
15 00: Positioning complete
REMARK
Block :
"1 block" is defined as all the data continuing from the positioning data in which
"continuous positioning control" or "continuous path control" is set in the operation
pattern (
Da.1
) to the positioning data in which "independent positioning control
(Positioning complete)" is set.