12 CONTROL SUB FUNCTIONS
[5] Teaching program example
The following shows a sequence program example for setting (writing) the
positioning data obtained with the teaching function to the QD75.
(1) Setting conditions
When setting the current feed value as the positioning address, write it
when the BUSY signal is OFF.
(2) Program example
The following example shows a program to carry out the teaching of axis
1 by the dedicated instruction "TEACH 1".
1) Move the workpiece to the target position using a JOG operation (or
an inching operation, a manual pulse generator operation).
PLC READY signal
QD75 READY signal
V
t
Forward run JOG start signal
Target position
BUSY signal
[X8]
n2n1 nx
Md.20 Current feed value
Example
Error detection signal
[XC]
[X0]
[Y0]
[Y8]