9 - 9
MELSEC-Q
9 MAJOR POSITIONING CONTROL
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Time
Positioning continue (11)
Dwell time
Positioning continue (11)
Start complete signal
BUSY signal
Positioning complete signal
Positioning start signal
Positioning
complete (00)
Address (+) direction
Address (-) direction
[Y10, Y11, Y12, Y13]
[X10, X11, X12, X13]
[XC, XD, XE, XF]
[X14, X15, X16, X17]
Fig. 9.3 Operation during continuous path control (Standard speed switching mode)
POINT
In the continuous path control, a speed variation will not occur using the near-pass
function when the positioning data No. is switched (Refer to Section 12.3.3 "Near-
pass function").
(2) Deceleration stop conditions during continuous path control
Deceleration stops are basically not carried out in continuous path control,
but the machine will carry out a deceleration stop to speed "0" in the
following cases (a) to (d).
(a) When the operation pattern of the positioning data currently being
executed is "continuous path control: 11", and the movement direction
of the positioning data currently being executed differs from that of the
next positioning data. (Only for 1-axis positioning control (Refer to the
"Point" in the next page.))
V
Positioning data No.2
Operation pattern : 00
Speed becomes 0
Positioning data No.1
Operation pattern : 11