15 - 37
MELSEC-Q
15 TROUBLESHOOTING
Related buffer memory
address
Axis 1 Axis 2 Axis 3 Axis 4
Set range
(Setting with sequence program)
Remedy
For command speed,
refer to Section 5.3
"List of positioning data"
1 to 1000000 [pulse/s]
1 to 2000000000 [mm/min or another]
Speed limit value
10
11
160
161
310
311
460
461
QD75P
:
1 to 200000 [pulse/s]
1 to 2000000000
[mm/min or another]
QD75D
:
1 to 1000000 [pulse/s]
1 to 2000000000
[mm/min or another]
Set the command speed to within the setting range.
1549 1649 1749 1849
<Teaching positioning data No.>
1 to 600
Set the positioning data No. to within the setting range.
1548 1648 1748 1848
<Teaching data selection>
0, 1
Set the teaching data selection set value to within the
setting range.
1538 1638 1738 1838
<Target position change request
flag>
1: Target position change request
• Do not turn ON the target position change request in
the following cases.
A control system other than ABS1, and INC1 is used.
During deceleration stop. An operating pattern
"continuous path control" is used.
• When the target position change address is outside
the stroke limit, correct the target position change
address. (Refer to Section 12.7.5)