Mitsubishi Electronics QD75P Video Game Controller User Manual


 
9 - 37
MELSEC-Q
9 MAJOR POSITIONING CONTROL
Restrictions
An error will occur and the positioning will not start in the following cases. The
machine will immediately stop if the error is detected during a positioning
operation.
If the movement amount of each axis exceeds "1073741824 (=2
30
)" when "0:
Composite speed" is set in "
Pr.20
Interpolation speed designation method"
... The "Outside linear movement amount range error (error code: 504)" occurs
at a positioning start.
(The maximum movement amount that can be set in "
Da.6
Positioning
address/movement amount" is "1073741824 (=2
30
)".)
Positioning data setting example
[Reference axis is designated as axis 1.]
The following table shows setting examples when "3-axis linear interpolation
control (INC linear 3)" is set in positioning data No. 1 of axis 1. (The required
values are also set in positioning data No. 1 of axis 2 and axis 3.)
Axis
Setting item
Axis 1
(reference
axis) setting
example
Axis 2
(interpolation
axis) setting
example
Axis 3
(interpolation
axis) setting
example
Setting details
Da.1
Operation pattern
Positioning
complete
––
Set "Positioning complete" assuming the next
positioning data will not be executed.
Da.2
Control system INC linear 3
Set incremental system 3-axis linear
interpolation control.
Da.3
Acceleration time
No.
1––
Designate the value set in "
Pr.25
Acceleration time 1" as the acceleration time
at start.
Da.4
Deceleration time
No.
0––
Designate the value set in "
Pr.10
Deceleration time 0" as the deceleration time
at deceleration.
Da.5
Axis to be
interpolated
–––
Setting not required (setting value will be
ignored).
When axis 1 is used as a reference axis, the
interpolation axes are axes 2 and 3.
Da.6
Positioning address/
movement amount
10000.0
µ
m 5000.0
µ
m 6000.0
µ
m
Set the movement amount. (Assuming "mm"
is set in "
Pr.1
Unit setting".)
Da.7
Arc address
Setting not required (setting value will be
ignored).
Da.8
Command speed
6000.00
mm/min
Set the speed during movement.
Da.9
Dwell time 500ms
Set the time the machine dwells after the
positioning stop (pulse output stop) to the
output of the positioning complete signal.
Axis 1 Positioning data No. 1
Da.10
M code 10
Set this when other sub operation commands
are issued in combination with the No. 1
positioning data.
Refer to Section 5.3 "List of positioning data" for information on the setting details.