11 - 9
MELSEC-Q
11 MANUAL CONTROL
Setting item Setting requirement
Factory-set initial value
(setting details)
Pr.25
Acceleration time 1 (Unit: pulse) 1000
Pr.26
Acceleration time 2 (Unit: pulse) 1000
Pr.27
Acceleration time 3 (Unit: pulse) 1000
Pr.28
Deceleration time 1 (Unit: pulse) 1000
Pr.29
Deceleration time 2 (Unit: pulse) 1000
Pr.30
Deceleration time 3 (Unit: pulse) 1000
Pr.31
JOG speed limit value (Unit: pulse/s) 20000
Pr.32
JOG operation acceleration time selection 0 (acceleration time 0)
Pr.33
JOG operation deceleration time selection 0 (deceleration time 0)
Pr.34
Acceleration/deceleration process selection
0 (trapezoidal acceleration/
deceleration processing)
Pr.35
S-pattern proportion (Unit: %) 100
Pr.36
Sudden stop deceleration time (Unit: ms) 1000
Pr.37
Stop group 1 sudden stop selection 0 (deceleration stop)
Pr.38
Stop group 2 sudden stop selection 0 (deceleration stop)
Parameters
Pr.39
Stop group 3 sudden stop selection 0 (deceleration stop)
: Setting always required.
: Set according to requirements (Leave set to the initial value when not used.)