578 CHAPTER 16: RADIUS AND SERVER GROUP COMMANDS
clear radius Resets parameters that were globally configured for RADIUS servers to
their default values.
Syntax
clear radius {deadtime | key | retransmit |
timeout }
deadtime — Number of minutes to wait after declaring an
unresponsive RADIUS server unavailable before retrying the RADIUS
server.
key — Password (shared secret key) used to authenticate to the
RADIUS server.
retransmit — Number of transmission attempts made before
declaring an unresponsive RADIUS server unavailable.
timeout — Number of seconds to wait for the RADIUS server to
respond before retransmitting.
Defaults — Global RADIUS parameters have the following default
values:
deadtime—0 (zero) minutes (The WX switch does not designate
unresponsive RADIUS servers as unavailable.)
key—No key
retransmit—3 (the total number of attempts, including the first
attempt)
timeout—5 seconds
Access — Enabled.
History —Introduced in MSS Version 3.0.
Usage — To override the globally set values on a particular RADIUS
server, use the set radius server command.
Examples — To reset all global RADIUS parameters to their factory
defaults, type the following commands:
WX4400# clear radius deadtime
success: change accepted.
WX4400# clear radius key
success: change accepted.
WX4400# clear radius retransmit
success: change accepted.