Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 3.0 RADXUSR1/RADXUSR2 EN | 86
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
U### Passcode U### User Group
Default: Refer to the program record sheet Default: Blank
Selection: Three to six digits ( 0 to 9) Selection: Blank, 1 to 8
Enter three to six digits to enable a pass code for the
master user in this group.
Create a group of up to 249 users (99 for the
D7412GV2) whose combinations can be enabled and
disabled using an automatic user window. This is the
number entered into the W# User Group for any
active W# User Window. Multiple windows can be
programmed for one user group (up to eight) within
one 24-hour period. For example, if User Group 1
has a window running from 8:00 AM (start time) to
4:00 PM (stop time), the users for that group can use
their pass codes only between that time. Between
4:00 PM that day and 8:00 AM the next day, the
users cannot use their pass codes.
To meet UL 864 requirements, enter at
least one Passcode.
User I.D.000 is the reserved user for
service personnel. The default service
pass code is 123.
The programmer does not allow you to
enter any pass code number that might
conflict with a duress pass code. The
programmer reserves the actual duress
pass code and the duress pass-code
number plus 1, duress pass-code number
plus 2, duress pass code-number minus
1, and duress pass-code number minus
2.
If Duress Type is set to 1, pass codes
within a range of 1 for existing pass
codes cannot be entered. If Duress Type
is set to 2, pass codes within a range of 2
cannot be entered. This rule applies even
if duress is disabled. For example, with
Duress Type set to 2, when a pass code
of 654321 is entered, 654322, 654323,
654320, and 654329 are reserved and
are not available to other users.
The authority to silence a bell is granted
to all pass codes regardless of their
authority level assignments. A user pass
code can silence a Fire or Burg bell as
long as any authority level is assigned to
the area where the bell can be silenced.
To enable this user’s pass code at all
times, leave U### User Group blank.
User Group Window times cannot be changed from
the keypad. When a window is assigned to a user
group, the users in that group rely on the window to
be active (within the start and stop times) for their
pass codes to function. The only way to disable the
window is by reprogramming the control panel from
the D5200 or remote programming software (RPS).
U### Area 1 [through Area 8] Auth
Default: Refer to the program record sheet
Selection: 1 to 14 or Blank
Assign an authority level to the user for this area.
Blank means the user has no authority in this area.
To meet UL 864 requirements, assign a
valid authority level to the Passcode to
silence bells.