Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 31
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
P## Supervised P## Scope
Default: No Default: No Printer
Selection:
Yes or No
Selection:
No Printer, Area, Account, Panel
Wide, Custom
Yes Only one printer can be installed for
this P## SDI address.
Panel
Wide
Printer prints all designated events
that occur panel-wide. A panel-wide
printer can cross account boundaries.
No More than one unsupervised printer
can be installed using this P## SDI
address and the same address DIP
switch setting.
Account Printer prints all designated events
that occur within any area with the
same account number in which this
printer is assigned.
Supervise this SDI address. Generate Trouble SDI
## Reports and local trouble annunciation if a
problem occurs with this printer or the SDI bus.
Area Printer prints all designated events
that occur in the area to which this
printer is assigned.
Unsupervised printers sharing the same
address setting print the same text.
Custom Printer prints all events occurring in
areas programmed Yes for this
prompt regardless of any boundary
restrictions.
Trouble SDI ## Reports are always
reported as Area 1, Account 1 Events
No Printer No printer installed at this address. If
a printer is connected, data does not
print.
regardless of where the SDI device is
assigned.
When P## Supervised is set to Yes and
Press the [SPACE] bar to scroll through the
selections. Press [ENTER] when the correct selection
appears in the display.
all Printer Event Groups (such as P##
Fire Events, P## Burglar Event, or P##
Usr Chng Evt) are set to No, the control
panel does not generate Trouble SDI ##
Reports for the printer if the D9131A
becomes disconnected.
The following prompts are visible only
when you program P## Scope to
Custom.
P## A1 [through A8] in Scope
Default: No
Selection:
Yes or No
Yes Include Area # Events in the scope of
this printer.
No Does not include Area # Events in
the scope of this printer.
Only available if P## Scope is programmed Custom.
This program item determines if events occurring in
an area print at this printer.
Refer to the report tables in Section 2.3
Routing on page 15 to identify the events
that print. Events programmed as No in
Routing still print at the local printer.
Individual events within the report group
cannot be suppressed for events printed
at the local printer.